PRODUCTS
Drug Solidification Point Measurement
Product Category:
- Products Detail
-
- Commodity name: Drug Solidification Point Measurement
JH-0613B Drug Solidification Point Measurement determines the highest temperature that remains unchanged in a short period of time when the drug is condensed from liquid to solid. Some medicines have a certain freezing point, and the purity changes, and the freezing point also changes accordingly. Determination of freezing point can distinguish or check the purity of drugs.
Drug Solidification Point Measurement

JH-0613B Drug Solidification Point Measurement determines the highest temperature that remains unchanged in a short period of time when the drug is condensed from liquid to solid. Some medicines have a certain freezing point, and the purity changes, and the freezing point also changes accordingly. Determination of freezing point can distinguish or check the purity of drugs.
This JH-0613B Drug Solidification Point Measurement is designed and manufactured according to the 0613 freezing point determination method of the four general rules of the 2015 edition of the Pharmacopoeia of the People's Republic of China.
The JH-0613B Drug Solidification Point Measurement Main technical features1. The design of this instrument fully complies with the requirements of the Pharmacopoeia of the People's Republic of China.
2. The design of the instrument is reasonable, easy to install and easy to use.
3. The inner and outer test tubes are fitted with ground joints, which is easy to operate.
4. The instrument uses a transparent high-boron glass beaker, which can observe the sample well.
5. Teflon fixed cover, strong and durable, strong corrosion resistance.
6. High-precision mercury thermometer, so that the temperature accuracy can reach 0.1 degrees.
JH-0613B Drug Solidification Point Measurement Main technical parameters and indicators1. Double-layer freezing point test tube:
The inner test tube of JH-0613B Drug Solidification Point Measurement is a test tube with an inner diameter of about 25mm and a length of about 170mm
The outer test tube is a test tube with an inner diameter of about 40mm and a length of about 160mm
2. Mercury thermometer: (0~50)℃, graduation 0.1℃, in line with the requirements of Pharmacopoeia (50~100)℃, graduation 0.1℃, in line with the requirements of Pharmacopoeia
3. Stirrer: Made of high boron glass, the upper end is slightly bent, and a small circle is cast at the end, with a diameter of about 18mm, and then bent into a right angle
4. 1000ml transparent boron glass beaker


JH-0613B Drug Solidification Point Measurement configuration list