PRODUCTS

+
  • intelligent-full-automatic-wet-laser-granulometer-124231.jpg

Intelligent Full-automatic Wet Laser Granulometer


JH5100-HIntelligent Full-automatic Wet Laser Granulometeris the latest product developed by our company. It is not a simple upgrade of 5100. It has won unanimous praise from customers since it was launched. JH5100-H is a wet-process fully automatic laser particle size analyzer, which adopts the most advanced international Mie scattering principle and convergent light Fourier transform optical path. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results.
  • Products Detail
    • Commodity name: Intelligent Full-automatic Wet Laser Granulometer

    JH5100-HIntelligent Full-automatic Wet Laser Granulometeris the latest product developed by our company. It is not a simple upgrade of 5100. It has won unanimous praise from customers since it was launched. JH5100-H is a wet-process fully automatic laser particle size analyzer, which adopts the most advanced international Mie scattering principle and convergent light Fourier transform optical path. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results.

    Intelligent Full-automatic Wet Laser Granulometer
    JH5100-HIntelligent Full-automatic Wet Laser Granulometeris the latest product developed by our company. It is not a simple upgrade of 5100. It has won unanimous praise from customers since it was launched. JH5100-H is a wet-process fully automatic laser particle size analyzer, which adopts the most advanced international Mie scattering principle and convergent light Fourier transform optical path. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results.

     

     

    First of all, thank you for your attention to Jiahang Instruments!

    Our company regards "creating the most stable domestic laser particle size instrument" as its own responsibility, and takes science and technology to create a brand, quality to enter the market, and reputation to win the world as its policy, and strives to create an ultra-stable and cost-effective domestic laser particle size instrument.

     

    The operation process of Intelligent Full-automatic Wet Laser Granulometer is all automatically controlled by the computer. The schematic diagram of the control system is as follows:

     

    Schematic diagram of the intelligent laser particle size analyzer control system

    Main performance characteristics of JH5100-H laser particle size analyzer:

    ★Advanced optical path design: JH5100-H Intelligent Full-automatic Wet Laser Granulometeradopts converging light Fourier transform test technology to ensure the maximum measurement range at the shortest focal length, which effectively improves the resolution of the instrument; the unique high-density detection unit enables 5100-H to have a super strong small particle Testing ability, high-density detection units make JH5100-H have super full-scale seamless testing ability.

    ★Fully sealed fiber semiconductor laser: JH5100-HIntelligent Full-automatic Wet Laser Granulometeradopts a highly stable and long-life fully sealed fiber semiconductor laser. The excellent stability makes JH5100-H have a strong test repeatability (helium-neon laser is optional).

    ★Automatic testing: truly fully automatic testing, all you have to do is put in the sample, no interference data and no manual selection of data.

    ★Ultrasonic anti-dry function: After painstaking research and development, JH5100-HIntelligent Full-automatic Wet Laser Granulometercan realize the ultrasonic anti-dry function, avoiding damage to the ultrasonic in the absence of water.

    ★Adjustable ultrasonic power: In order to meet the dispersion needs of different samples, JH5100-H realizes adjustable ultrasonic power from 0 to 20 milliwatts.

    ★Dust-proof and shock-proof design: The overall instrument is sealed, which greatly improves the service life of internal components. The unique anti-shock structure can effectively avoid the interference of external vibration to the instrument, making the test results more stable and reliable.

    ★Strong anti-corrosion design (optional): According to the actual needs of customers, it can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (such as acetone, phenol, n-hexane and other organic solvents).

    ★Automatic centering: Exclusively adopts the combination technology of mechanical center and optical center, the automatic adjustment and positioning of the optical path is more accurate, reaching the micron level; at the same time, the adjustment speed of the optical path is faster and the adjustment can be completed in 15 seconds at the fastest. The self-developed automatic centering system consists of stepping motors, precision guide rails, precision controllers and software systems. The minimum step distance is 0.2 microns, ensuring that the laser beam focus always passes through the center of the detector, improving the accuracy of test results and testing repeatability. The automatic centering system is the standard configuration of all models of Niket laser particle size analyzers.

    Optical path automatic centering function diagram

    ★Unique micro test system: JH5100-H specially designed a set of micro circulation system for the field of sewage treatment, which can obtain the particle size distribution of particles in filtered water with a very small amount of impurities. The entire dispersion circulation system has been optimized, and the dispersion medium is greater than 8 It can be tested in milliliters, and it has really achieved micro-level testing; it has been well applied to the analysis of the median particle size of water quality in oil production plants, sewage treatment stations and other places.

    ★Exhaust-free air bubble design: The brand-new design prevents air bubbles from entering the test sample window during the entire test, avoiding air bubble interference.

    ★Sample residue-free design: The instrument pipeline and drainage structure have been optimized, and there is no fluid residue in the instrument pipeline and circulating pump, so as to avoid the impact on the next test data.

    ★Sample window quick change device: The newly designed sample window quick change device makes the sample window replacement more convenient and quick.

    ★Dew point measurement: The fogging of the sample window will affect the accuracy of the measurement. Such a test result has no practical significance. JH5100-H Intelligent Full-automatic Wet Laser Granulometer is equipped with a fog point measurement system. Once fogging occurs, the software will automatically prompt.

     

    The main technical parameters:

     

    Specifications

    JH5100-H (high configuration)

    Executive standard

    ISO 13320-1:1999; GB/T19077.1-2008

    Test Range

    0.1μm -600μm

    Number of detector channels

    88

    accuracy error

    <1% (D50 value of national standard sample)

    repeatability error

    <0.5% (D50 value of national standard sample)

    Air bubble free

    It has a bubble-free design, and the data is more accurate without bubble interference

    Misoperation Protection

    The instrument has a self-protection function for misoperation, and the instrument does not respond to misoperation

    Laser parameters

    Imported fiber output high power semiconductor laserλ= 635nm, p>10mW

    Optical path calibration

    Optical path automatic calibration

    Intelligent operation mode

    One-button fully automatic software operation mode

    test speed

    <1min/time (excluding sample dispersion time)

    built-in scatter method

     

     

    ultrasound

    Frequency: f=40KHz, power: p=80W, time: adjustable at will; with ultrasonic anti-dry

    to stir

    Circulation stirring integrated design, speed: 100-33950rpm speed adjustable

    cycle

    Cycle rated flow: 0-10L/min adjustable Rated power: 25W

    Shading detection

    The instrument has a unique real-time detection function of shading to ensure more accurate sample addition

    sample cell

    Self-designed boiling sample pool, better dispersion effect, capacity: 190-600mL can be tested normally

    Dustproof and shockproof design

    The whole machine adopts dustproof and shockproof design

    Micro injection (optional)

    The instrument can be equipped with a micro-automatic testing device, and 10 ml can be used for cyclic testing (optional)

    Anti-corrosion design (optional)

    It can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (all organic solvents such as acetone, phenol, n-hexane, etc.).

     SoftwareFunction

    testing report

    The test report can export Word, Excel, picture (Bmp) and text (Text) and other documents in various forms, satisfying the need to view test reports and quote test results in scientific research articles on any occasion

    DIY

    User-defined data to be displayed, find the percentage according to the particle size, find the particle size according to the percentage or

    Statistical methods

    Volume distribution and number distribution to meet different statistical methods for particle size distribution in different industries

    statistical comparison

    Statistical comparative analysis can be carried out for multiple test results, and the difference between different batches of samples, samples before and after processing, and test results at different times can be clearly compared, which has strong practical significance for the quality control of industrial raw materials

    analysis mode

    Including free distribution, R-R distribution and logarithmic normal distribution, grading statistical mode according to the purpose, etc., to meet the different requirements of different industries for the particle size statistics of the tested samples

    display template

    Calculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Radius distance, consistency, interval accumulation, etc.

    Intelligent operation mode

    Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better.

    multilingual support

    Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.

    volume

    980mm*410mm*450mm

    weight

    30Kg

Hot Products

Messages