PRODUCTS
0.1-2000 Automatic Wet Laser Granulometer
Product Category:
- Products Detail
-
- Commodity name: 0.1-2000 Automatic Wet Laser Granulometer
JH6100-C 0.1-2000 Automatic Wet Laser Granulometer is the latest product developed by our company, and has won unanimous praise from customers since it was launched. JH6100-C 0.1-2000 Automatic Wet Laser Granulometer adopts the most advanced Mie scattering principle and convergent light Fourier transform optical path in the world. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results. The unique wet circulation dispersion system ensures that there is no particle deposition during the particle test, and there is no waste liquid accumulation after the test is drained, which ensures the accuracy of the second test and makes the test results more real and reliable; at the same time, it adopts the design of no residue in the pipeline, The accuracy of testing different samples is guaranteed. The superior optical path automatic calibration system highlights the unique advantages of JH6100-C 0.1-2000 Automatic Wet Laser Granulometer.
0.1-2000 Automatic Wet Laser Granulometer
First of all, thank you for your attention to JH6100-C wet intelligent automatic laser particle size analyzer!
JH6100-C 0.1-2000 Automatic Wet Laser Granulometer is the latest product developed by our company, and has won unanimous praise from customers since it was launched. JH6100-C 0.1-2000 Automatic Wet Laser Granulometer adopts the most advanced Mie scattering principle and convergent light Fourier transform optical path in the world. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results. The unique wet circulation dispersion system ensures that there is no particle deposition during the particle test, and there is no waste liquid accumulation after the test is drained, which ensures the accuracy of the second test and makes the test results more real and reliable; at the same time, it adopts the design of no residue in the pipeline, The accuracy of testing different samples is guaranteed. The superior optical path automatic calibration system highlights the unique advantages of JH6100-C 0.1-2000 Automatic Wet Laser Granulometer.
Main performance characteristics of JH6100-C laser particle size analyzer:
★Advanced optical path design: JH6100-C0.1-2000 Automatic Wet Laser Granulometeradopts converging light Fourier transform test technology to ensure the maximum range at the shortest focal length, which effectively improves the resolution of the instrument; the unique high-density detection unit enables 6100-C 0.1-2000 Automatic Wet Laser Granulometer to have a super strong small particle Test ability, high-density detection unit makes JH6100-C have super full-scale seamless test ability.
★Fully sealed fiber semiconductor laser: JH6100-C0.1-2000 Automatic Wet Laser Granulometeradopts a highly stable and long-life fully sealed imported fiber semiconductor laser. The excellent stability makes JH6100-C have super test repeatability, and the life span is more than 30,000 hours.
★Laser power monitoring and automatic adjustment: exclusive use of constant power laser, real-time detection of laser power and automatic adjustment function, effectively avoiding the problem of laser power attenuation caused by long-term use. At the same time, a constant current, constant voltage and high filter laser power supply is used to effectively prolong the life of the laser, and the normal use can reach more than 30,000 hours.
★Laser intelligent management system: JH6100-C 0.1-2000 Automatic Wet Laser Granulometer is the first to add a laser intelligent management system. The intelligent management system monitors the working status of the instrument in real time. Once it receives a work order, the intelligent management system will instantly light up the laser. to achieve a stable working state. After the sample test is completed, the intelligent management system will automatically turn off the laser, and the laser will basically not attenuate. In theory, there is no need to replace the laser for life.
★Automatic testing: truly fully automatic testing, all you have to do is put in the sample, no interference data and no manual selection of data.
★Ultrasonic anti-dry function: After painstaking research and development, JH6100-C0.1-2000 Automatic Wet Laser Granulometercan realize ultrasonic anti-dry function, avoiding damage to the ultrasonic in the absence of water.
★Adjustable ultrasonic power: In order to meet the dispersion needs of different samples, JH6100-C 0.1-2000 Automatic Wet Laser Granulometer realizes adjustable ultrasonic power from 0 to 20 milliwatts.
★Dust-proof and shock-proof design: The overall instrument is sealed, which greatly improves the service life of internal components. The unique anti-shock structure can effectively avoid the interference of external vibration to the instrument, making the test results more stable and reliable.
★Strong anti-corrosion design (optional): According to the actual needs of customers, it can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (such as acetone, phenol, n-hexane and other organic solvents).
★Automatic centering: Exclusively adopts the combination technology of mechanical center and optical center, the automatic adjustment and positioning of the optical path is more accurate, reaching the micron level; at the same time, the adjustment speed of the optical path is faster and the adjustment can be completed in 15 seconds at the fastest. The self-developed automatic centering system consists of stepping motors, precision guide rails, precision controllers and software systems. The minimum step distance is 0.2 microns, ensuring that the laser beam focus always passes through the center of the detector, improving the accuracy of test results and testing repeatability. The automatic centering system is the standard configuration of all models of Niket laser particle size analyzers.
★Unique micro-circulation system: The entire dispersing circulation system has been optimally designed, and the dispersion medium can be circulated for testing when the dispersion medium is larger than 120 ml, which truly achieves the micro-circulation test; the optimized design ensures that there is no waste residue after drainage, ensuring the accuracy of the next test result accuracy. (trace test is optional)
★Exhaust-free air bubble design: The brand-new design prevents air bubbles from entering the test sample window during the entire test, avoiding air bubble interference.
★Sample residue-free design: The instrument pipeline and drainage structure have been optimized, and there is no fluid residue in the instrument pipeline and circulating pump, so as to avoid the impact on the next test data.
★Sample window quick change device: The newly designed sample window quick change device makes the sample window replacement more convenient and quick.
★Dew point measurement: The fogging of the sample window will affect the accuracy of the measurement. Such a test result has no practical significance. JH6100-C 0.1-2000 Automatic Wet Laser Granulometer is equipped with a fogging point measurement system. Once fogging occurs, the software will automatically prompt.
Stability and repeatability reach foreign Malvern instrument standards
The main technical parameters:
Hot Products
Messages
0086 17721148861
+86-17721148861
E-mail