PRODUCTS

+
  • 1-800-micron-spray-laser-granulomete-1143890.jpg

1-800 Micron Spray Laser Granulomete

Product Category:


JH-PW180-B1-800 Micron Spray Laser Granulomete is an upgraded product of PS180 spray particle size analyzer. JH-PW180-B adopts split design and has a wider scope of application. The performance is more stable, the measurement range is larger, and it is suitable for various complex test environments. At the same time, JH-PW180-B is dust-proof.
  • Products Detail
    • Commodity name: 1-800 Micron Spray Laser Granulomete

    JH-PW180-B1-800 Micron Spray Laser Granulomete is an upgraded product of PS180 spray particle size analyzer. JH-PW180-B adopts split design and has a wider scope of application. The performance is more stable, the measurement range is larger, and it is suitable for various complex test environments. At the same time, JH-PW180-B is dust-proof.

    1-800 Micron Spray Laser Granulomete

    JH-PW180-B1-800 Micron Spray Laser Granulomete is an upgraded product of PS180 spray particle size analyzer. JH-PW180-B adopts split design and has a wider scope of application. The performance is more stable, the measurement range is larger, and it is suitable for various complex test environments. At the same time, JH-PW180-B is dust-proof.


    First of all, thank you for your attention to Jiahang Instruments!Our company regards "creating the most stable domestic laser particle size instrument" as its own responsibility, and takes science and technology to create a brand, quality to enter the market, and reputation to win the world as its policy, and strives to create an ultra-stable and cost-effective domestic laser particle size instrument.

     

    Main performance characteristics ofJH-PW180-B 1-800 Micron Spray Laser Granulomete:

     JH-PW180-B1-800 Micron Spray Laser Granulomete adopts a split structure, which can test long-distance samples. JH-PW180-B adopts a large platform, which can meet the normal test at a distance of 0.1 meters to 10 meters even if it is used in one piece.

    Advanced optical path design:

    JH-PW180-B1-800 Micron Spray Laser Granulomete adopts the principle of Fraunhofer diffraction and typical parallel optical path design, and is equipped with a high-power semiconductor laser; the unique high-density detection unit makes JH-PW180-B have super small particle testing capabilities , JH-PW180-B seamless test within 1μm ~ 800μm. At the same time, JH-PW180-B has added an automatic optical path adjustment device, which is convenient for operation and prolongs the service life of the instrument.

    High power semiconductor laser:

    JH-PW180-B1-800 Micron Spray Laser Granulomete uses a high-power semiconductor laser, which enhances the resolution of the instrument and makes small particles nowhere to hide.

    Optical path automatic calibration:

    JH-PW180-B 1-800 Micron Spray Laser Granulomete  is the first to add the automatic centering function in the spray particle size analyzer. The optical path automatic adjustment system added by JH-PW180-B ensures the stability and accuracy of the instrument measurement. At the same time, the work intensity of the operator is greatly reduced.

    Imported lens:

    JH-PW180-B adopts Canon of Japan as the main lens, which has small distortion and high imaging. The receiving end adopts a large-diameter long-focus lens with a diameter of 150mm, which makes particle detection more accurate.

    Ultra-wide range:

    The measuring range of JH-PW180-B has reached 1μm~800μm.

    Fill light positioning:

    JH-PW180-B1-800 Micron Spray Laser Granulomete has uniquely added auxiliary light positioning function. When positioning, two laser beams at the transmitter emit at the same time. After the two points at the receiver match, the receiver can start the automatic adjustment system of the optical path, which greatly simplifies the adjustment difficulty.

    Powerful analysis software:

    Powerful analysis software can record the particle size distribution of all droplets in all laser beams at any time. Test results can be continuously recorded and statistically analyzed by moving the spray within the laser beam.

    JH-PW180-B


    The main technical parameters:

     

    Specifications

    JH-PW180-B

    Executive standard

    ISO 13320-1:1999; GB/T19077.1-2008

    Test Range

    1μm-800μm

    Number of detector channels

    66

    accuracy error

    <3% (D50 value of national standard sample)

    repeatability error

    <3% (D50 value of national standard sample)

    Injection method

    open sampling

    Instrument structure

    Split type or one-piece type optional

    Split guide rail (optional)

    Separate instrument, the test area can be equipped with guide rails within 3 meters

    Laser parameters

    Imported fiber optic output high power laserλ= 650nm, power 1-40mw adjustable

    key parameter

    measurement area

     

    Split type: the instrument can be tested normally within the range of 0.1 to 10 meters

    Integrated: instrument 100mm to 340mm

    lens

    Canon High Performance Lenses

    lens protection

    air curtain protection

    Injection method

    Spray (including mist and solid powder)

    automatic centering

    The instrument automatically adjusts the optical path, and the computer software automatically completes it with one key.

    operating mode

    computer operation

    test speed

    <1min/time

    weight

    25Kg

     

    software function

    testing report

    The test report can export Word, Excel, picture (Bmp) and text (Text) and other documents in various forms, satisfying the need to view test reports and quote test results in scientific research articles on any occasion

    DIY

    User-defined data to be displayed, find the percentage according to the particle size, find the particle size according to the percentage or

    Statistical methods

    Volume distribution and number distribution to meet different statistical methods for particle size distribution in different industries

    statistical comparison

    Statistical comparative analysis can be carried out for multiple test results, and the difference between different batches of samples, samples before and after processing, and test results at different times can be clearly compared, which has strong practical significance for the quality control of industrial raw materials

    analysis mode

    Including free distribution, R-R distribution and logarithmic normal distribution, grading statistical mode according to the purpose, etc., to meet the different requirements of different industries for the particle size statistics of the tested samples

    display template

    Calculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Radius distance, consistency, interval accumulation, etc.

    Intelligent operation mode

    Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better.

    multilingual support

    Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.

Hot Products