PRODUCTS

+
  • open-flash-point-test-device-1334586.jpg

Open Flash Point Test Device

Product Category:


The manufacture of this JH-267 Open Flash Point Test Device conforms to the requirements stipulated in the industry standard SH/T 0318 of the People's Republic of China "Technical Conditions for Open Flash Point Tester" and Shanghai Enterprise Standard Q/YXYY 23 "SYD-267 Open Flash Point Tester for Petroleum Products".
  • Products Detail
    • Commodity name: Open Flash Point Test Device

    The manufacture of this JH-267 Open Flash Point Test Device conforms to the requirements stipulated in the industry standard SH/T 0318 of the People's Republic of China "Technical Conditions for Open Flash Point Tester" and Shanghai Enterprise Standard Q/YXYY 23 "SYD-267 Open Flash Point Tester for Petroleum Products".

    Open Flash Point Test Device

    The manufacture of this JH-267 Open Flash Point Test Device conforms to the requirements stipulated in the industry standard SH/T 0318 of the People's Republic of China "Technical Conditions for Open Flash Point Tester" and Shanghai Enterprise Standard Q/YXYY 23 "SYD-267 Open Flash Point Tester for Petroleum Products". 

    JH-267 Open Flash Point Test Device is suitable for determining the flash point and ignition point of lubricating oil and dark petroleum products according to the method stipulated in the People's Republic of China Standard GB/T 267 "Determination of Flash Point and Fire Point of Petroleum Products (Open Cup Method)".

    JH-267 Open Flash Point Test Device Main technical features

    1. The design of this JH-267 Open Flash Point Test Device fully complies with the requirements of SH/T 0318 and GB/T 267 standards.
    2. The heating power is continuous and stepless adjustable, the power level is directly displayed by the ammeter, and the temperature control method is advanced and reasonable.
    3. It adopts desktop and compact structure design, which is easy to operate and use.
    The biggest feature of this instrument is: simple structure, continuous and stepless adjustable heating power.

    JH-267 Open Flash Point Test Device Main technical parameters and indicators

    1. Working power supply: AC(220±10%)V, 50Hz.
    2. Outer crucible (1) Material: high-quality carbon structural steel with black plating on the surface;
    ⑵ Inner diameter of upper opening: Φ100㎜±5㎜;
    (3) Height: 50㎜±5㎜;
    ⑷ Bottom inner diameter: Φ56㎜±2㎜.
    3. Inner crucible ⑴Material: high-quality carbon structural steel with black plating on the surface;
    ⑵ Inner diameter of upper opening: Φ64㎜±1㎜;
    (3) Height: 47㎜±1㎜;
    ⑷ Bottom inner diameter: 38㎜±1㎜;
    ⑸ Scale line: There is a scale line at 12mm and 18mm from the edge of the upper mouth.
    4. Gas conduit: The diameter of the nozzle is Φ0.8㎜~Φ1㎜, and the surface of the inner hole is smooth so that the flame can be adjusted by 3㎜~4㎜.
    5. Heater: electric furnace heating, heating power 1000W adjustable.
    6. Thermometer: (0~360) ℃, graduation 1 ℃, the technical conditions comply with the provisions of GB/T 514.
    7. Power consumption of the whole machine: not more than 1100W.
    8. Dimensions: 310㎜×230㎜×400㎜ (length×width×height, excluding thermometer).
     